CANLI
Yükleniyor Veriler getiriliyor…
türk tıp dizini Özgün Makale Scopus
Surgical Outcomes of Ex PRESS Mini Glaucoma Shunt Implantation
Turkiye Klinikleri Journal of Medical Sciences 2014 Cilt 34 Sayı 3
Scopus Eşleşmesi Bulundu
34
Cilt
293-297
Sayfa
🔓
Açık Erişim
Scopus Yazarları: Gulfidan Bitirgen, Hürkan Kerimoğlu, Banu Bozkurt, Hanife Yumak Erkoça, Mehmet Okka
Özet
Objective: To evaluate intraocular pressure (IOP) lowering effect and safety of Ex-PRESS® mini glaucoma drainage implant (Alcon, Fort Worth, TX) for the surgical treatment of glaucoma. Material and Methods: The data of the subjects who underwent Ex-PRESS® mini glaucoma shunt (P-50) implantation surgery in 2011 and 2012 were retrospectively reviewed. IOP before and after the treatment, visual acuity, the number of medications and complications were analyzed. Success was defined as final IOP of 6-21 mmHg with or without antiglaucomatous medications. Results: Thirty two eyes of 32 patients were included in the study. The mean age of patients and mean follow-up time were 54.43±14.56 years (range 20-77 years) and 6.34±2.95 months (range 3-16 months), respectively. Mean pretreatment IOP was 30.71±4.72 mmHg, while it was 13.21±3.51 mmHg (p<0.001) at the first week, 14.46±4.08 mmHg (p<0.001) in the first month, 14.37±2.93 mmHg (p<0.001) in the third month, 13.78±2.98 mmHg (p<0.001) in the sixth month, and 14.53±2.27 mmHg (p<0.001) in the last visit. An IOP less than 21 mmHg was achieved in all eyes in the last visit. The median value of preoperative total antiglaucomatous medications was 4.0 (3.0-5.0), however topical medications were discontinued in 81.3% of patients in the last visit. There were no complications during the follow-up period except one case of early postoperative choroidal effusion. Conclusion: Ex-PRESS® mini glaucoma shunt implantation is supposed to be an effective and safe method for the surgical treatment of glaucoma. It also helped to reduce the number of antiglaucoma medications, thus improving both the quality of life of the patients and their compliance to therapy.
Anahtar Kelimeler (Scopus)
Glaucoma Glaucoma drainage implants Intraocular pressure
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2014 yılı verileri
Turkiye Klinikleri Journal of Medical Sciences
Q4
SJR Quartile
0,131
SJR Skoru
18
H-Index
Kategoriler: Medicine (miscellaneous) (Q4)
Alanlar: Medicine
Ülke: Turkey · Turkiye Klinikleri
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Glaucoma Glaucoma drainage implants Intraocular pressure

Makale Bilgileri

Dergi Turkiye Klinikleri Journal of Medical Sciences
ISSN 1300-0292
Yıl 2014 / 1. ay
Cilt / Sayı 34 / 3
Sayfalar 293 – 297
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks türk tıp dizini
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 5 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı OKKA MEHMET,BİTİRGEN GÜLFİDAN,KERİMOĞLU HÜRKAN,BOZKURT BANU,hanife yumak erkoça
YÖKSİS ID 1103334