CANLI
Yükleniyor Veriler getiriliyor…
SSCI Özgün Makale Scopus
Accuracy of two electronic apex locators in primary teeth with and without apical resorption a laboratory study
International Endodontic Journal 2008 Cilt 41 Sayı 5
Scopus Eşleşmesi Bulundu
24
Atıf
41
Cilt
436-441
Sayfa
Scopus Yazarları: Gül Tosun, Y. Sener, Ali Erdemir, Ayce Unverdi Eldeniz, U. Sermet
Özet
Tosun G, Erdemir A, Eldeniz AU, Sermet U, Sener Y. Accuracy of two electronic apex locators in primary teeth with and without apical resorption: a laboratory study. International Endodontic Journal. Aim To evaluate the accuracy of the Root ZX (J Morita Corp., Kyoto, Japan) and Tri Auto ZX (J Morita Corp.) devices for measuring root canal length in primary teeth with and without apical resorption. Methodology Thirty-four extracted human primary molar teeth with resorption and 19 primary teeth without resorption were collected. After endodontic access preparation, the actual lengths of the teeth were determined. The teeth were then embedded in an alginate model to determine the electronic working length measurement. Statistical evaluation was completed using Student's t-tests. Results For the Root ZX, there was no significant difference between those teeth with root resorption and those without. However, for the Tri Auto ZX, there was a significant difference in the electronic measurements between those teeth with root resorption and those without (P < 0.05). Significant differences were found amongst the measurements of the two apex locators (P < 0.05). For root canals with resorption, the respective accuracy rates (within ±0.5 mm) of Root ZX and Tri Auto ZX were 83.33% and 89.47%; within ±1 mm, the Root ZX and Tri Auto ZX demonstrated 98.95% and 100% accuracy, respectively. For root canals with no resorption, the percentage of measurements within ±0.5 mm of the apical construction was 89.28% for the Root ZX and 80.35% for the Tri Auto ZX. The accuracy within ±1 mm of the Root ZX and the Tri Auto ZX was 98.22% and 100%, respectively. Conclusion Within the limitations of this laboratory study, the presence of resorption affected the performance of the Tri Auto ZX more than the Root ZX. © 2008 International Endodontic Journal.
Anahtar Kelimeler (Scopus)
Electronic apex locators Primary teeth with apical resorption Root ZX Tri Auto ZX

Anahtar Kelimeler

Electronic apex locators Primary teeth with apical resorption Root ZX Tri Auto ZX

Makale Bilgileri

Dergi International Endodontic Journal
ISSN 0143-2885
Yıl 2008 / 5. ay
Cilt / Sayı 41 / 5
Sayfalar 436 – 441
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SSCI
YÖKSİS Atıf 12
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 5 kişi
Erişim Türü Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- DİŞ HEKİMLİĞİ

YÖKSİS Yazar Kaydı

Yazar Adı TOSUN GÜL,ERDEMİR ALİ,ÜNVERDİ ELDENİZ AYÇE,ÜLKÜ SERMET,ŞENER YAĞMUR
YÖKSİS ID 844033

Metrikler

YÖKSİS Atıf 12
Scopus Atıf 24
Yazar Sayısı 5