SSCI
Özgün Makale
Scopus
Comparison of the ganglion cell complex and retinal nerve fibre layer measurements using Fourier domain optical coherence tomography to detect ganglion cell loss in non arteritic anterior ischaemic optic neuropathy
BRITISH JOURNAL OF OPHTHALMOLOGY
2013
Cilt 97
Sayı 8
Scopus Eşleşmesi Bulundu
38
Atıf
97
Cilt
1045-1050
Sayfa
Scopus Yazarları: Berker Bakbak, Şansal Gedik, Şaban Gönül, Bengu Ekinci Koktekir
Özet
Objective: To evaluate the diagnostic ability of macular ganglion cell complex (GCC) and peripapillary nerve fibre layer (NFL) measurements to detect ganglion cell loss (GCL) in patients with non-arteritic anterior ischaemic optic neuropathy (NAION), at the chronic stage. Methods: This study included 10 eyes from 10 patients with NAION and 15 eyes from 15 age-matched healthy subjects. The measurements included the GCC thicknesses as average, superior and inferior, the GCC parameters as focal loss volume (FLV) and global loss volume (GLV), the NFL thicknesses as average, superior hemisphere and inferior hemisphere, and the disc parameters as rim area and rim volume. The curves for the area under the receiver operator characteristic (AUROC) were generated to assess the ability of each parameter to detect GCL. Results: The patient group had significantly lower GCC thicknesses than the control group (p<0.001, <0.001 and 0.004, for the GCC average, superior and inferior, respectively), and also significantly higher FLV and GLV measurements (p<0.001). The NFL thicknesses were found to be significantly lower in the patient group than the control subjects ( p<0.001). Among all the parameters, the FLV and the GLV had the highest levels of AUROC values (1.000, 0.990, respectively). Conclusions: The FLV and the GLV showed the strongest abilities to detect GCL in patients with NAION. In addition, peripapillary NFL thickness was comparable to macular GCC thickness in detecting GCL. Therefore, macular GCC scans may provide a good alternative or a complementary practice to NFL scans in the detection of GCL in patients with NAION.
Makale Bilgileri
Dergi
BRITISH JOURNAL OF OPHTHALMOLOGY
ISSN
0007-1161
Yıl
2013
/ 8. ay
Cilt / Sayı
97
/ 8
Sayfalar
1045 – 1050
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SSCI
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
4 kişi
Erişim Türü
Basılı
Alan
Sağlık Bilimleri Temel Alanı-
Göz Hastalıkları
YÖKSİS Yazar Kaydı
Yazar Adı
GÖNÜL ŞABAN,EKİNCİ KÖKTEKİR BENGÜ,BAKBAK BERKER,GEDİK ŞANSAL
YÖKSİS ID
1313126
Hızlı Erişim
Metrikler
Scopus Atıf
38
Yazar Sayısı
4