CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Radiation dose and diagnostic accuracy of high pitch dual source coronary angiography in the evaluation of coronary artery stenoses
Diagnostic and Interventional Imaging 2016 Cilt 97 Sayı 4
Scopus Eşleşmesi Bulundu
25
Atıf
97
Cilt
461-469
Sayfa
🔓
Açık Erişim
Scopus Yazarları: A. Avci, Y. Paksoy, Mesut Sivri, Hasan Erdogan, Lütfi Saltuk Demir, M. Koplay, Kenan Demir, Ibrahim Guler
Özet
Purpose: “Flash Spiral” imaging is a new prospective ECG-triggered spiral scan mode that uses a very high-pitch for coronary computed tomography angiography (CTA). This enables complete image acquisition within one cardiac cycle with a very low radiation exposure. The aim of this study was to investigate the diagnostic accuracy, image quality, and effective radiation dose of prospectively ECG-triggered high-pitch spiral method (Flash spiral mode) of coronary CTA using dual-source technology for the evaluation of coronary artery stenoses. Material and methods: The study included 186 consecutive patients (115 men, 71 women; mean age: 53.37 years) who underwent coronary CTA. Coronary CTA was performed with a 128 × 2-slice dual-source CT (Somatom Definition Flash, Siemens, Germany) using a prospectively ECG-triggered high-pitch spiral mode. Patients were divided into three groups according to heart rate (≤ 65 bpm, 66–75 bpm, ≥ 76 bpm) and body mass index (BMI) (20–24 kg/m<sup>2</sup>, 25–29 kg/m<sup>2</sup>, 30–34 kg/m<sup>2</sup>) values. The correlation between heart rates, image quality and BMI values are investigated. A four-point scale (1 = excellent, 4 = poor/non-diagnostic) was used to rank the comparative image quality. Effective radiation doses were calculated. Also the correlation between radiation dose, sex and BMI values were investigated. In addition, diagnostic accuracy of CTA for detection of significant (≥ 50%) coronary artery stenoses was compared with invasive coronary angiography findings of 612 vessel segments in 38 patients. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rate were calculated. Results: A total of 2976 coronary artery segments were present. Of all coronary artery segments, 2381 (80%) had an image quality score of 1, and 1.5% segments were rated as “poor/non-diagnostic”. When the correlation between heart rate and image quality is investigated, there was a significant difference between ≤ 65 bpm and ≥ 76 bpm groups. However, there was no significant difference between ≤ 65 bpm and 66–75 bpm groups. The mean effective dose was found as 1.3 mSv (min: 0.5, max: 2.4 mSv). The correlation between effective radiation dose and BMI was moderate. However, the correlation between gender and radiation dose was significant. Sensitivity, specificity, negative predictive value and accuracy of coronary CTA on a per-vessel segment were 90.1%, 97.4%, 98.6%, and 96.5%, respectively. Conclusions: Prospectively ECG-triggered high-pitch spiral mode coronary CTA provides high image quality and diagnostic accuracy, with very low radiation dose for evaluation and exclusion of coronary artery stenoses.
Anahtar Kelimeler (Scopus)
High-pitch spiral acquisition Dual source CT Radiation dose Coronary angiography Image quality
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2016 yılı verileri
Diagnostic and Interventional Imaging
Q2
SJR Quartile
0,740
SJR Skoru
63
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q2) · Radiological and Ultrasound Technology (Q2) · Radiology, Nuclear Medicine and Imaging (Q2)
Alanlar: Health Professions · Medicine
Ülke: France · Elsevier Masson s.r.l.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

High-pitch spiral acquisition Dual source CT Radiation dose Coronary angiography Image quality

Makale Bilgileri

Dergi Diagnostic and Interventional Imaging
ISSN 22115684
Yıl 2016 / 4. ay
Cilt / Sayı 97 / 4
Sayfalar 461 – 469
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
TEŞV Puanı 12,00
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 7 kişi
Erişim Türü Basılı+Elektronik
Erişim Linki Makaleye Git
Alan Sağlık Bilimleri Temel Alanı- Radyoloji

YÖKSİS Yazar Kaydı

Yazar Adı KOPLAY MUSTAFA,Hasan Erdogan,Ahmet Avci,SİVRİ MESUT,DEMİR KENAN,GÜLER İBRAHİM,PAKSOY YAHYA
YÖKSİS ID 747559

Metrikler

Scopus Atıf 25
TEŞV Puanı 12,00
Yazar Sayısı 7