CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus 🌍 Uluslararası
Peri implant crevicular fluid levels of cathepsin K RANKL and OPG around standard short and mini dental implants after prosthodontic loading
J Periodontal Implant Sci 2015 Cilt 45 Sayı 5
Scopus Eşleşmesi Bulundu
45
Cilt
169-177
Sayfa
Scopus Yazarları: Raif Alan, İsmail Marakoğlu, S. Haliloglu
Özet
Purpose: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin-K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. Methods: A total of 78 non-submerged implants (Euroteknika, Aesthetica+2, Sallanches, France) were installed in 30 subjects (13 male, 17 female, range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. Results: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG:sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. Conclusions: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.
Anahtar Kelimeler (Scopus)
Alveolar bone loss Cathepsin K Dental implants Osteoprotegerin RANK ligand

Anahtar Kelimeler

Alveolar bone loss Cathepsin K Dental implants Osteoprotegerin RANK ligand

Makale Bilgileri

Dergi J Periodontal Implant Sci
ISSN 20932278
Yıl 2015 / 10. ay
Cilt / Sayı 45 / 5
Sayfalar 169 – 177
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
TEŞV Puanı 6,00
Yayın Dili İngilizce
Ülke GÜNEY KORE Uluslararası
Kapsam Uluslararası
Toplam Yazar 3 kişi
Erişim Türü Basılı
Alan Sağlık Bilimleri Temel Alanı- Periodontoloji

YÖKSİS Yazar Kaydı

Yazar Adı ALAN RAİF,MARAKOĞLU İSMAİL,HALİLOĞLU SEYFULLAH
YÖKSİS ID 728406

Metrikler

TEŞV Puanı 6,00
Yazar Sayısı 3