Scopus Eşleşmesi Bulundu
8
Atıf
291
Cilt
1-12
Sayfa
Scopus Yazarları: Murat Yıldırım, Omer Sise, Mevlut Dogan, Hamdi Şükür Kılıç
Özet
In this paper we present numerical modelling results for linear time-of-flight mass spectrometers (TOFMSs) with higher-order space focusing. A brief account of the TOFMS theory is given together with optimal geometries and electric fields which provide space focusing condition (i.e. the zero variation in ion time-of-flight caused by a change in initial position). The effect of the initial velocity distribution, a dominating factor that restricts resolution in TOFMSs, on the time-width of a peak in the mass spectrum was demonstrated. The results have shown that the limitations of the mass resolution by different initial velocities of the ions play a significant role in determining the order of space focusing required in practice. At room temperature no significant improvement in the mass resolution can be expected by increasing the order of space focus, because the time spread due to the velocity dispersion and "turn-around" time of the ion with a mass of 100 amu is about ∼ 20 ns. Therefore, the optimum resolving power is about m / Δ m = 200, which is also experimentally measured using a homemade TOFMS. Nevertheless, the theoretical analysis of the space focusing (no thermal energy distribution) is necessary as it provides a reference for judging the importance of velocity distributions, as deviations from the ideal case. © 2010 Elsevier B.V. All rights reserved.
Anahtar Kelimeler (Scopus)
Time-of-flight mass spectrometer
Wiley and McLaren
Mass resolution
Simion
Space focusing
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2010 yılı verileri
International Journal of Mass Spectrometry
Q1
SJR Quartile
1,044
SJR Skoru
126
H-Index
Kategoriler: Condensed Matter Physics (Q1) · Instrumentation (Q1) · Physical and Theoretical Chemistry (Q2) · Spectroscopy (Q2)
Alanlar: Chemistry · Physics and Astronomy
Ülke: Netherlands
· Elsevier B.V.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Electrostatic Lens System
Simion
TOF
Wiley Mclaren
Time-of-flight mass spectrometer
Wiley and McLaren
Mass resolution
Space focusing
mavi = YÖKSİS
yeşil = Scopus
Makale Bilgileri
Dergi
International Journal of Mass Spectrometry
ISSN
1387-3806
Yıl
2010
/ 3. ay
Cilt / Sayı
291
Sayfalar
1 – 12
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q3
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
4 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Fen Bilimleri ve Matematik Temel Alanı-
Fizik
YÖKSİS Yazar Kaydı
Yazar Adı
YILDIRIM MURAT,ŞİŞE ÖMER,DOĞAN MEVLÜT,KILIÇ HAMDİ ŞÜKÜR
YÖKSİS ID
385778
Hızlı Erişim
Metrikler
Scopus Atıf
8
JCR Quartile
Q3
Yazar Sayısı
4