Scopus Eşleşmesi Bulundu
7
Atıf
30
Cilt
13-23
Sayfa
Scopus Yazarları: Mahmut Kusdemir, Ali Riza Cetin, Alev Özsoy, Tuʇba Toz, Funda Öztürk Bozkurt, Mutlu Ozcan
Özet
The objectives of this study were to investigate the adhesion of a universal adhesive used either in total-etch (TE) or self-etch (SE) mode with and without 2% chlorhexidine digluconate cavity disinfectant (CHX) or sodium fluoride/hydroxyethyl methacrylate (NaF/HEMA) to dentin. Dentin surfaces of extracted human non-carious third molar teeth (N = 18) were exposed and randomly assigned to two groups. Half of the teeth were conditioned with TE and the others with SE adhesive mode. The teeth were then randomly divided into two groups where half were cleaned with 2% CHX (Cavity Cleanser, Bisco, CC) and the other half with NaF/HEMA (Aqua Prep F, Bisco, APF). Control groups in TE (C1) and SE (C2) adhesive system did not receive any cavity disinfectant. Dentin surfaces were conditioned with universal adhesive (Single Bond Universal, SBU) and resin composite blocks (3 M Z550) were bonded incrementally on the conditioned dentin using a mold. The teeth were stored in water for 48 h, and from each tooth, beam-shaped specimens (1 mm2) were prepared (n = 14, per group). Microtensile bond strength (MBS) was measured using a universal testing machine (1 mm/min). Data (MPa) were analyzed using one-way ANOVA and Tukeys test (α∗= 0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale (m), and shape (0) values were calculated. Mean MTBS results (MPa) showed significant difference between the experimental groups (p = 0.001) and were in descending order as follows: C1-CC (32.8 ±∗6.4)a <∗C1 (24.4 ±∗5.2)b <∗C2 (21.1 ±∗4.8)b <∗C1-APF (19.3 ±∗4.4)b <∗C2-CC (14.1 ±∗4.1)c <∗C2-APF (8.1 ±∗2.1)d. C1 and C2 presented non-significant bond strength of the resin composite bonded with SBU (p >∗0.05). CC application significantly increased the bond strength in TE mode, but significant reduction was observed when used in SE mode (p <∗0.05). The use of APF did not significantly decrease the bond strength in TE mode, but significant reduction was observed when used in SE mode. Considering Weibull parameters, characteristics of adhesion seem to be less reliable for C2-CC (m = 3.86) and more reliable for C1-CC (m = 6.77). Failure types were predominantly adhesive between the dentin and the adhesive resin. Mixed failures were more common for both C1 and C2 and total etch-CC combination.
Anahtar Kelimeler (Scopus)
Adhesion
adhesive resin
cavity disinfectant
chlorhexidine
universal bond system
Anahtar Kelimeler
Adhesion
adhesive resin
cavity disinfectant
chlorhexidine
universal bond system
Makale Bilgileri
Dergi
Journal of Adhesion Science and Technology
ISSN
0169-4243
Yıl
2015
/ 9. ay
Cilt / Sayı
30
/ 1
Sayfalar
13 – 23
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SSCI
TEŞV Puanı
135,00
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
5 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı-
Restoratif Diş Tedavisi
YÖKSİS Yazar Kaydı
Yazar Adı
KUŞDEMİR MAHMUT,ÇETİN ALİ RIZA,ÖZSOY ALEV,TOZ TUĞBA,ÖZTÜRK BOZKURT FUNDA
YÖKSİS ID
372964
Hızlı Erişim
Metrikler
Scopus Atıf
7
TEŞV Puanı
135,00
Yazar Sayısı
5