Scopus Eşleşmesi Bulundu
1
Atıf
40
Cilt
181-184
Sayfa
Scopus Yazarları: Berker Bakbak, Şansal Gedik, Omer Kamil Dogan, Bengu Ekinci Koktekir, Şaban Gönül
Özet
OBJECTIVE:: To evaluate the effect of room illumination on the measurement of anterior segment parameters. METHODS:: In this comparative study, measurements of anterior segment parameters of 25 eyes of 25 healthy patients were performed by optical low-coherence reflectometry (OLCR). Measurements were taken under photopic conditions (150 lux) and under mesopic conditions (3 lux). Paired t test by SPSS 16.0 was used to compare the anterior segment measurements performed in both conditions. A P value lower than 0.05 was accepted as statistically significant. RESULTS:: The mean age of the patients was 27.09±1.72 years (range, 20-40 years). Of the anterior segment parameters, axial length and keratometry did not show significant difference between photopic and mesopic conditions (P=0.541 and P=0.812, respectively). The mean anterior chamber depth measurements was 3.04±0.35 mm and 3.06±0.35 mm, whereas the mean lens thickness was 3.75±0.36 mm and 3.77±0.36 mm in the mesopic and photopic conditions, respectively. The mean pupil diameter measurement was 4.86±0.70 mm under photopic conditions and 6.36±0.94 mm under mesopic conditions. The anterior chamber depth, lens thickness, and pupil diameter showed significant difference between photopic and mesopic conditions (P=0.01, P=0.006, and P=0.0001, respectively). CONCLUSION:: Anterior chamber depth, lens thickness, and pupil diameter were affected by the changes in luminance while performing measurements with OLCR. Considering the age of the study group, further studies are needed to test the measurement of accommodation amplitude. © 2014 Contact Lens Association of Ophthalmologists.
Anahtar Kelimeler (Scopus)
Anterior segment parameters
Luminance
Optical lowcoherence reflectometer
Phakic lenses
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2014 yılı verileri
Eye and Contact Lens
Q2
SJR Quartile
0,676
SJR Skoru
70
H-Index
Kategoriler: Medicine (miscellaneous) (Q2) · Ophthalmology (Q2)
Alanlar: Medicine
Ülke: United States
· Lippincott Williams and Wilkins Ltd.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Anterior segment parameters
Luminance
Optical lowcoherence reflectometer
Phakic lenses
Makale Bilgileri
Dergi
Eye & Contact Lens: Science & Clinical Practice
ISSN
1542-2321
Yıl
2014
/ 1. ay
Cilt / Sayı
40
/ 3
Sayfalar
181 – 184
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
5 kişi
Erişim Türü
Elektronik
Erişim Linki
Makaleye Git
Alan
Sağlık Bilimleri Temel Alanı-
Göz Hastalıkları
YÖKSİS Yazar Kaydı
Yazar Adı
Koktekir Bengu Ekinci, Gonul Saban, Bakbak Berker, Gedik Sansal, Dogan Omer Kamil
Hızlı Erişim
Metrikler
Scopus Atıf
1
Yazar Sayısı
5